Development Intent
Case officer · Hammersmith And Fulham Planning

Benjamin Hicks.

Last recorded decision Feb 2024 — no decisions in this record since

A case officer at Hammersmith And Fulham with an approval rate of 93% across 28 decided planning applications, spanning 9 wards.[1] Decision speed and appeal performance publish when decision notices are ingested.

Planning officer28 decisions93% approvalSave
Hammersmith And Fulham · ward map
Approval rate — by ward
Lower ~68%
Higher ~90%
ShowingAll years · subscriber →across all years on record — a period re-scopes the headline figures and the trend
At a glanceEach metric links to the investigation behind it
All investigations →
28
Applications
2023–24
Approval rate over time — tougher or softer 🔒Dashed line = London average

Not enough dated decisions for a trend yet.

What they decide — by application type
How they compareVersus peers
Approval rate93% · 23rd of 45
higher is betterdashed = London avg
Decision time · publishes with decision notices
in development
Appeal overturn · publishes with decision notices
in development
How this officer decides — from their own reports24 officer reports parsed
10%
Approves despite concerns
of approvals record a documented reservation
0%
Negotiated approvals
approvals mentioning revisions/amendments
0%
"On balance" reports
reports using explicit balancing language
71%
Bespoke reasoning
of report text written for the case, not recited
What they write about — vs Hammersmith And Fulham's average officer

Topic mentions per 1,000 words of their own report text (boilerplate stripped), indexed against all parsed Hammersmith And Fulham reports. Attention, not stance.

Daylight & sunlight
3.46× borough avg
Bulk & massing
2.67× borough avg
Outlook & amenity
1.23× borough avg
Character & heritage
1.22× borough avg

Mark = borough average (1×). Bar capped at 2×.

How they reason — coded from their reports

Hicks's caseload is dominated by pod and roof extensions on narrow rear gardens, and he is distinctive for framing a marginal 45-degree breach at one specific distance point within an irregularly-shaped garden boundary as 'negligible' by cross-referencing the SAME extension's compliance at a different point along the same irregular boundary (e.g. citing both a 3.7m and a 5.6m measurement along one garden's boundary). He consistently checks whether a proposed extension's projection depth 'aligns with the established rear building line' set by NAMED comparable extensions at specific neighbouring addresses, citing their individual depths in metres.

Observable habits

· on irregularly-shaped garden boundaries, cross-references a marginal 45-degree breach at one measured point against compliance at a different measured point along the SAME boundary, framing the breach as negligible in context

· checks whether a proposed extension's projection depth aligns with an 'established rear building line' set by NAMED comparable extensions at specific neighbouring addresses, citing their individual depths in metres

· on marginal breaches where the existing rear outrigger already slightly infringes the 45-degree line, assesses whether the new works would 'significantly exacerbate' that pre-existing situation rather than treating any addition as fatal

What their reports consistently look for

· multiple measured points along an irregular garden boundary, to contextualise whether a marginal 45-degree breach is genuinely negligible

· the specific depths in metres of named comparable extensions at neighbouring addresses that establish the 'rear building line' for the terrace

· whether new works would significantly exacerbate a pre-existing marginal 45-degree infringement already caused by the existing rear outrigger

Assigned Benjamin Hicks on a live case?What they pay attention to, how they reason, and what their reports consistently look for — so you can address it before they raise it.Subscribe to unlock →
In their own words

at the 5.6m distance, which covers about 72% of the width, the pod extension would comfortably fit within the visual bulk envelope. Thus, the minor breach at the 3.7m distance further underscores its negligible effect.

2023/03301/FUL

A comparable extension depth can be observed at adjoining no. 27 (2.5m), as well as further along the terrace at no. 39 (3m). Therefore, it is considered that the projection aligns with the established rear building line set by these extensions.

2024/00060/FUL

Measured from 24 published Hammersmith And Fulham officer reports written by this officer, with recited policy boilerplate stripped before any counting. These describe how this officer works and writes — they are not outcome predictions. Every quote is from a named public report.

Policy playbook — what this officer cites[3]

The policies this officer cites most in their own reports — times cited across 24 parsed reports. Whether refusals citing each survive appeal isn't traced per policy yet.

DC1Built environment quality and integration
22 times cited
DC4High standard of design for alterations and extensions
22 times cited
HO11Detailed Residential Standards
19 times cited
DC8Heritage and conservation: Buildings at risk
16 times cited
CC3Flood Risk Assessment Requirement
13 times cited
CC4Minimising surface water run-off with Sustainable Drainage Systems
13 times cited
CC11Noise and Vibration Control for Developments
13 times cited
DC6Respecting architectural character with replacement windows
11 times cited
Which policies this officer leans on is subscriber intelligenceSubscribe to unlock →
Decisions by ward

Where this officer's caseload concentrates, 2023–24.[1] Click the map above to focus this page on a ward, or a row to open the ward.

Recent applications
Address
Reference
Type
Outcome
Date
2024/00117/FUL
Full Planning Application
Approved
2024-05-30
2023/02948/FUL
Full Planning Application
Approved
2024-05-07
2024/00117/FUL
Full Planning Application
Approved
2024-05-30
2023/02948/FUL
Full Planning Application
Approved
2024-05-07
Full application history locked
Subscribe to see all 28 decisions →
Consultants approved most— subscriber data
1. Mr Ray Reilly / RPR Planning Ltd
2. Mrs Jaspal Kaur / Stones Architects Ltd
3. Mr Sam De Silva / F Line Designs Ltd
4. Mr Giles Hoeg / Hoeg Architects Ltd
At a glance
OfficerBenjamin Hicks
RolePlanning officer
Experience
Applications28 (2023–24)
Approval rate93%
London approval avg81%
Who decides here
GovernmentMayor of LondonCouncilCommitteeOfficersDecisionsApplicantsInspectorate
Related investigations
When committees overrule officers like this one →
How often members depart from officer recommendations, and how those overrides fare at appeal.
How much gets decided without a committee →
The delegated share by borough and officer — where the real power over decisions sits.
Sources & method
  1. [1]Applications decided, approval rate, per-year trend and ward breakdown — London Borough of Hammersmith And Fulham planning register and published decision notices, 2023–24. · methodology
  2. [2]Appeal overturn and decision-time benchmarks — Planning Inspectorate (PINS) appeal decisions and application date pairs; not yet computed per officer, shown as a dash until they are. · PINS appeals casework
  3. [3]Condition load — mean effective conditions attached to Hammersmith And Fulham decision notices (grant/split), parsed from the published notice text; a borough figure, not yet split per case officer.
  4. [4]"How this officer decides", the policy playbook and all quotes — parsed from 24 published Hammersmith And Fulham officer reports written by this officer, recited policy boilerplate stripped before counting; disposition text coded from their own reasoning with every quote machine-verified verbatim. Descriptive of how they work — not outcome predictions.
Methodology is published in full so every number is traceable to its primary source.