Development Intent
Planning AtlasEnfieldBowesApplication
Planning Application

22/01022/FUL

Brownlow Lodge Brownlow Road London N11 2BL

Full / Other PlanningBowes wardDevelopment Control teams: Area: SOUTH Code: DCAREA_S
Submission
22 Mar 2022
Target
24 May 2022
Decision
12 May 2022
Outcome
Refused
Delegated decisionRefused
12 May 2022
Decided by Ronny Ferley under delegated powers
Loading map…
Scheme description

Creation of additional third floor roof extension to provide 2Nos. 1 bedroom self contained flats

Why it was refused
Reason 1

The proposal by reason of its inappropriate height, siting and scale, as well as obtrusive form and significant occupation of the host roof would constitute an intrusive, incongruous and dominant form of overdevelopment of the host roof. This would give rise to a protuberant, top heavy and conspicuous roof form visually at odds with the surrounding vertical emphasis and associated roofscape along the street, to stand out negatively and appear as unwieldy, stark and discordant to the character of the vertical built form and rhythm of the roofscape, in a visually jarring manner to the context. As such, the proposed scheme is contrary to the National Planning Policy Framework (NPPF, 2021), Policy D4 of the London Plan (2021), DMD 6, DMD 8, DMD 13, DMD 37 and DMD 38 of the Development Management Document (2014) and Policy CP30 of the Core Strategy (2010). Dated: 12 May 2022 Authorised on behalf of: Mr A Higham Head of Development Management Development Management, London Borough Enfield, PO Box 53, Civic Centre, Silver Street, Enfield, Middlesex, EN1 3XE If you have any questions about this decision, please contact the planning officer ronny.ferley@enfield.gov.uk. List of plans and documents referred to in this Notice: Title/Number Version TYPE MB/BL/P01 Drawing MB BL P02 Drawing MB BL P03 Drawing MB BL P04 Drawing MB BL P05 Drawing MB BL P06 Drawing Site Location Plan Drawing Block Plan Drawing Sustainability and Energy Statement by Melin (Not Dated) Supporting Information Daylight and Sunlight Assessment BRE Report (Mar 2022) Ref: P122740- Supporting Information Design & Access Statement by Altaras Architecture 1000 Supporting Information Additional Information Rights of Applicants Aggrieved by Decision of Local Planning Authority

Policies cited
D4
DMD6
DMD8
DMD13
DMD37
DMD38
CP30
NPPF
Parties
Applicant
Mr Michael Byrne
Ward
Bowes
Appeal
Appeal decided
Outcome: Appeal Dismissed
Timeline
22 Mar 2022
Application submitted
29 Mar 2022
Application validated
12 May 2022
Delegated decision: Refused
Appeal: Appeal decided
Supporting documents · 16
Decision Notice12 May 2022View ↗
Officer Report12 May 2022View ↗
Application Form - Without Personal Data22 Mar 2022View ↗
The location plan22 Mar 2022View ↗
EXISTING AND PROPOSED BLOCK22 Mar 2022View ↗
PROPOSED SITE PLAN22 Mar 2022View ↗
EXISTING FLOOR PLANS22 Mar 2022View ↗
PROPOSED THIRD FLOOR22 Mar 2022View ↗
FRONT REAR ELEVATIONS22 Mar 2022View ↗
SIDE ELEVATIONS22 Mar 2022View ↗
SECTION - EXISTING22 Mar 2022View ↗
SECTION - PROPOSED22 Mar 2022View ↗
SUSTAINABILITY APPRAISAL22 Mar 2022View ↗
DAYLIGHT OR SUNLIGHT ASSESSMENT22 Mar 2022View ↗
DESIGN AND ACCESS STATEMENT22 Mar 2022View ↗
COMMUNITY INFRASTRUCTURE LEVY - COMPLETED FORM22 Mar 2022View ↗
View Application Page ↗
Data from the Enfield planning register.
Summary
Reference
22/01022/FUL
Ward
Type
Full
Applicant
Mr Michael Byrne
Submitted
22 Mar 2022
Decision date
12 May 2022
Council
Decision
Refused
Decision route
Delegated (officer)
How long, really
7
wks · this application
Submission → decision
Public response
Objections
0
In support
0
Total comments
0